Repair Central Air Fan Motor Not Working Tutorial

Home > Not Working > Central Air Fan Motor Not Working

Central Air Fan Motor Not Working

Contents

This was the first search result. Room temp starts to rise rapidly again and at around 28 deg C room temp the compressor starts again but stops after 15-20 minutes when room temp has only fallen to Thank you. The fan also moves no problem when unit turns on. http://phpbbconstructor.com/not-working/car-fan-motor-not-working.html

Run cap visually looks great no bulges. There is no way for the outdoor unit to put smells into the home. I question every step for a possible alternate interpretation. Our central A.C.

Air Conditioner Outside Unit Fan Not Working

Any thoughts on this? Minor bends can be corrected manually; damaged blades need to be replaced. Inside I had cool air. This is very simple.

The unit continued to run with heat and spewing fumes into the air. They also said they will charge 85 an hour just to look at it now. Please advise, it's hot. Why Is My Ac Outside Unit Not Turning On travelerone7 weeks ago Service tech replaced the dual capacitor & unit ran for 5 weeks.

To post questions, help other DIYers and reduce advertising (like the one on your left), join our DIY community. any suggestions rather than buying an entire new system? Any ideas? Sign in Transcript 828,636 views 2,779 Like this video?

I decided to go into the house and turn the thermostat back on to run more testing, and low and behold, the unit kicked on and is now cooling the house. Ac Blower Not Working If this is the case, you can flip the switch at your circuit breaker back on. Note down how the wires connect. I will try your fan trick and see if this could be the capacitor.

Ac Inside Fan Not Working

Just ask us! http://georgebrazilhvac.com/blog/why-is-my-outdoor-a-c-units-fan-not-spinning Thanks for reading! Air Conditioner Outside Unit Fan Not Working since it is not the motor nor capacitor due to they being tested out what else can cause this issue? Ac Fan Not Working In Car Todd15 months ago Thanks - I guess that's to be expected with something this old. (Would it run for a minute if it was shorted, though?) Cre8tor15 months ago from Ohio

They have been out here several times and it has worked a while but then the same problem. his comment is here Any ideas what they might be missing?The AC capacitor was replaced in 2012 along with the Condensate Line cleaned out that same year. Could it be aleak of coolant gas? Faith3 months ago My a/c will not shut off when hitting the desired temperature. Ac Compressor Not Running

I checked the pipe to see if it was frozen because it was running on auto from 88 degrees down to 78 degrees last night.Any suggestions would be greatly appreciated as Cre8tor2 months ago from Ohio Author Faith - I'm glad you're up and running!Lou - Those units use the same concepts but the design is quite different. i tried calling them but they're closed for the holiday. http://phpbbconstructor.com/not-working/carrier-condenser-fan-motor-not-working.html If you have that, then it's more likely the contactor.

It was nice to have a trained tech look at the unit to insure nothing else was wrong, but $400 was a bit much in my opinion. Ac Fan Capacitor i bought a new blower motor and a new capacitor twice since i returned the first one thinking it was damaged. See the Capacitors link just below Condenser fan blades loose, wobbling, bent or loose Turn off power, visually inspect fan and fan blades: are blades cut, bent, or damaged?

Don't assume that what's there is correct and replace it with that.

The AC unit does have a Heat Pump but it was 86 degrees and the ac unit is in the direct sunlight. The A coil isn't dirty or clogged. The main indicator you mentioned: "Loud hum, but the fan is not spinning). Ac Unit Not Turning On They either send a jolt to start a motor or send jolts to keep a motor running.

Advertise Find a Contractor Interactive How-to's About Us Terms of Use Privacy Policy Cookie Policy Site Map DoItYourself.com is an INTERNET BRANDS company. You and your stick just took over the job of the start capacitor. Fan spins freely and bearings do not grind. navigate here What is this part called or where can I find it?

Could this be a safety measure to protect the compressor from these temperatures in DFW or do we have a problem with the unit somewhere?Seems like if we turn the power If refrigerant is added, the leak should be located and repaired.On the compressor, use a multi-meter to measure the voltage going to the compressor. I shit the breaker off and sound was gone. If the ohmmeter shows an "open" circuit (no connection between the leads) on either winding, the compressor is bad and must be replaced.The compressor is not a good "do it yourself"

Also when tech gave me new capacitor the numbers were slightly off. If the compressor and fan stop together (but the thermostat continues to call for cooling and the evaporator/cooling unit/blower assembly continues to run) there may be a refrigerant metering device problem, The fan was still going i don't see any ice anywhere. I followed every step of your instructions and it works!Thanks again!

Even so, the motor uses the 5 mf side of the capacitor which is correctly sized. Sparky Channel 228,062 views 21:29 Testing a 4 Wire Condenser Fan Motor | Louisville Kentucky Air Conditioner Repair - Duration: 25:58. To determine if the thermostat is defective, set the air conditioner to cooling and then use a multimeter to test the thermostat for continuity. Let them fix it properly.

Thanks for sharing. After driving all over God's green earth I finally found a place willing to sell me a capacitor. Finally a senior tech came out and recognized that the fan required a different capacitor than what was initially changed in. If power is getting to the fan motor, but the motor won’t run, this also indicates that the motor is defective and should be replaced.

Mine isn't humming. However, repeated power issues should be looked at by a professional.Blocked air filter. Discharging the Power in the Capacitor You've already shut off power to the air conditioner, but now you will have to discharge the power in the capacitor. The picture below is the schematic for your unit.

What should I doReply Jim Plummer says: September 2, 2016 at 2:04 pmJamie,I would first make certain the outdoor unit is getting 220 volt power.If it is, I would then shut The filter should be clean.I am assuming this unit has performed satisfactorily in past years at similar temperatures. I'm hoping I don't have to buy an entirely new outdoor unit because apparently they don't sell my model anymore and I'd have to get all the pipes and whatnot in Cre8tor2 months ago from Ohio Author hitmanch47 - It sounds like the motor is bad.